From e1b28866578dcda2e33d53ec9c213bf78451ff9b Mon Sep 17 00:00:00 2001 From: sindoring Date: Fri, 17 Jul 2026 09:41:05 +0400 Subject: [PATCH] docs(M03): accept ADT water load pipeline state --- .../M03-RND-ADT-WATER-LOAD-PIPELINE-001.md | 11 +++++-- targets/03-renderer-facade.md | 30 +++++++++++++++---- 2 files changed, 33 insertions(+), 8 deletions(-) diff --git a/coordination/claims/M03-RND-ADT-WATER-LOAD-PIPELINE-001.md b/coordination/claims/M03-RND-ADT-WATER-LOAD-PIPELINE-001.md index 957e88a..b49014f 100644 --- a/coordination/claims/M03-RND-ADT-WATER-LOAD-PIPELINE-001.md +++ b/coordination/claims/M03-RND-ADT-WATER-LOAD-PIPELINE-001.md @@ -80,12 +80,15 @@ budget, stale-result and scene finalization behavior. ## Status -- State: ready for integration +- State: accepted - Done: pipeline state implemented; loader enqueue/start/publish/drain/release/ reset/shutdown/metrics adapters migrated; required documentation added -- Next: integrate and run post-merge smoke on master +- Next: continue liquid parse/finalization extraction or another remaining M03 + service boundary - Blocked by: + + ## Handoff - Commit: `b7c036f` @@ -104,5 +107,9 @@ budget, stale-result and scene finalization behavior. `docs/modules/adt-water-load-pipeline-state.md`; module registry, world renderer and `RENDER.md`; data-flow/state/sequence/dependency diagrams, ownership, threading, failure/recovery, profiles, performance limit and source map included. +- Integration: merged as `f470775`; post-merge water pipeline (`cases=12`, + `iterations=100`, `elapsed_ms=86.935`), shutdown, renderer materials, facade, + internal-access (`private_symbols=36`), `7/7` manifest, documentation and + coordination gates passed. diff --git a/targets/03-renderer-facade.md b/targets/03-renderer-facade.md index 2463d2c..2759594 100644 --- a/targets/03-renderer-facade.md +++ b/targets/03-renderer-facade.md @@ -27,7 +27,7 @@ Runtime и Editor используют facade; planner/scheduler тестиру ## Evidence - Date: 2026-07-17 -- Revision/worktree: master merges `7ece2ab`, `7e35de7`, `80cb084`, `d6e5b53`, `c69abd6`, `606770c`, `630a0c1`, `f36fabb`, `24aef13`, `2342430`, `396be5e`, `f88bf97`, `3f84717`, `d2cb52f`, `f9e5a4f`, `c06aed5`, `a878e7c`, `60603e1`, `b4955d6`, `ada0fd9`; +- Revision/worktree: master merges `7ece2ab`, `7e35de7`, `80cb084`, `d6e5b53`, `c69abd6`, `606770c`, `630a0c1`, `f36fabb`, `24aef13`, `2342430`, `396be5e`, `f88bf97`, `3f84717`, `d2cb52f`, `f9e5a4f`, `c06aed5`, `a878e7c`, `60603e1`, `b4955d6`, `ada0fd9`, `f470775`; packages `M03-RND-SCHEDULER-001`, `M03-RND-INTERNAL-ACCESS-GATE-001`, `M03-RND-FACADE-GROUND-QUERY-001`, `M03-RND-FACADE-ENVIRONMENT-001`, `M03-RND-FACADE-ENTITY-001`, `M03-RND-TERRAIN-CACHE-SERVICE-001`, @@ -41,7 +41,8 @@ Runtime и Editor используют facade; planner/scheduler тестиру `M03-RND-WMO-RENDER-BUILD-PLANNER-001`, `M03-RND-WMO-RENDER-BUILD-QUEUE-001`, `M03-RND-WMO-RENDER-RESOURCE-CACHE-001`, - `M03-RND-WMO-SCENE-RESOURCE-CACHE-001` + `M03-RND-WMO-SCENE-RESOURCE-CACHE-001`, + `M03-RND-ADT-WATER-LOAD-PIPELINE-001` - Commands: dedicated scheduler/planner/facade/focus/coordinate/manifest/shutdown headless verifiers; Godot cold editor parse; coordination, documentation and diff gates. - Results: scheduler `cases=6 iterations=20000 elapsed_ms=10.216`; planner @@ -109,6 +110,13 @@ Runtime и Editor используют facade; planner/scheduler тестиру Post-merge scene state (`40.113ms`), render state (`43.434ms`), shutdown, WMO queue/resolver, facade, internal-access `40`, `7/7` manifest, documentation and coordination gates remained green. + ADT water load pipeline state passed `cases=12 iterations=100 + elapsed_ms=86.170`; its initial direct no-`.godot` run passed (`94.576ms`), + WMO caches/queue/planner/registry/resolver/material/shutdown and 18 adjacent + M2/terrain/facade/scheduler/streaming/coordinate regressions passed, and the + checkpoint dry-run retained `7/7` plans. Post-merge water state (`86.935ms`), + shutdown, renderer materials, facade, internal-access `36`, `7/7` manifest, + documentation and coordination gates remained green. M02 terrain-query regression remained green (13 pre-existing expired M00 claim warnings). - Fidelity comparison: all 16 historical operation limits and drain sites were @@ -159,6 +167,12 @@ Runtime и Editor используют facade; planner/scheduler тестиру the prior transient-reset versus final-shutdown lifetime. File-size limits, `PackedScene` probe instantiation, WMOBuilder metadata validation and probe-node destruction remain loader-owned before state accepts a scene. + ADT water requests retain FIFO order and tile-key deduplication; tile release + removes pending requests without cancelling active work, task completion and + result publication order are unchanged, and the mutex remains limited to the + worker/main-thread mailbox. The loader still owns ADT parsing, concurrency and + profile limits, stale tile/path/root rejection, `WATER_FINALIZE` permits, + water Node construction/attachment and `water_loaded` timing. No new build-12340 parity claim is made; asset-backed visual/p95/p99 comparison remains pending. - Changed files: scene-free scheduler and verifier; streamer budget composition/ permit delegation; scheduler module spec; world renderer/module registry/RENDER notes; @@ -180,9 +194,11 @@ Runtime и Editor используют facade; planner/scheduler тестиру reset adapters, cached WMO PackedScene/missing/request state and loader file-size/I/O/probe/ validation/reset adapters, + ADT water pending/task/result pipeline state and loader enqueue/start/publish/ + drain/release/reset/shutdown/metrics adapters, expanded facade/internal-access/coordinate verifiers; work-package claims and this evidence. -- Remaining risks: queue storage length and worker concurrency/stale-result logic - remain streamer-owned; cancellation stops new permits but does not interrupt +- Remaining risks: worker concurrency and stale-result validation remain + streamer-owned; cancellation stops new permits but does not interrupt in-flight work; the environment snapshot currently covers world time but not weather or indoor state; entity PackedScene loading is synchronous and not accepted for network-scale hot paths; terrain cache is entry-count bounded without Mesh-byte @@ -197,5 +213,7 @@ Runtime и Editor используют facade; planner/scheduler тестиру WMO ResourceLoader/FileAccess I/O, live fallback and group materialization remain in the loader; asset-backed WMO placement/portal/material/leak/p95/p99 evidence remains pending; - M03 still needs further terrain/M2/WMO/liquid service extraction - and dependency/performance acceptance. + ADT water parsing, main-thread materialization and active worker interruption + remain loader-owned, and asset-backed MH2O/MCLQ traversal/leak/p95/p99/ + original-client evidence is pending; M03 still needs further terrain/M2/WMO/ + liquid service extraction and dependency/performance acceptance.